HI98594 Portable Multiparameter pH/EC/Turbidity/DO with Bluetooth
search
  • HI98594 Portable Multiparameter pH/EC/Turbidity/DO with Bluetooth
  • HI98594 Portable Multiparameter pH/EC/Turbidity/DO with Bluetooth
  • HI98594 Portable Multiparameter pH/EC/Turbidity/DO with Bluetooth
  • HI98594 Portable Multiparameter pH/EC/Turbidity/DO with Bluetooth
  • HI98594 Portable Multiparameter pH/EC/Turbidity/DO with Bluetooth

Water quality. 10m probe. HI98594. Portable multiparameter meter, 14 parameters

€3,700.00

Measurement of 14 parameters

This meter can display 1 to 12 parameters simultaneously, user selectable.

  • Hydrogen Potential (pH)
  • Millivolts (mV)
  • Redox Potential (ORP)
  • Dissolved Oxygen (ppm)
  • Dissolved Oxygen (%)
  • Conductivity EC
  • Conductivity EC (absolute)
  • Resistivity
  • Total Dissolved Solids (TDS)
  • Salinity
  • Seawater Sigma Density
  • Turbidity
  • Atmospheric Pressure
Quantity
In Stock

pH / mV
Range 0.00 to 14.00 pH* / ±600.0 mV
Resolution 0.01 pH / 0.1 mV
Accuracy ±0.02 pH / ±1.2 mV
Calibration • 1 point using HI9828-25 quick calibration solution
• Up to 3 points using pH 4.01, pH 6.86, pH 7.01, pH 9.18, pH 10.01 standard buffers and a custom buffer
ORP
Range ±2000.0 mV
Resolution 0.1 mV
Accuracy ±1.0 mV
Calibration Automatic at one custom point (relative mV)
Dissolved Oxygen
Range 0.0 to 500.0 % saturation; 0.00 to 50.00 ppm (mg/L)
Resolution 0.1 % saturation; 0.01 ppm (mg/L)
Accuracy • ±1.5 % of reading from 0.0 to 200.0 % saturation
• ±5 % of reading from 200.0 to 500.0 % saturation
• ±1.5 % of reading from 0.00 to 20.00 mg/L
• ±5 % of reading from 20.00 to 50.00 mg/L
Calibration • One point, quick calibration in water-saturated air
• One or two points, at 100 % and 0 %
• One point, using a custom solution (% saturation or mg/L)
Pressure compensation Automatic 450 to 850 mmHg
EC
Range 0 to 200 mS/cm; 0 to 400 mS/cm (absolute)
Resolution • Manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm
• Automatic: 1 µS/cm (0-9999 µS/cm); 0.01 mS/cm (10.00-99.99 mS/cm); 0.1 mS/cm (100.0-400.0 mS/cm)
• Automatic (mS/cm): 0.001 mS/cm (0.000-9.999 mS/cm); 0.01 mS/cm (10.00-99.99 mS/cm); 0.1 mS/cm (100.0-400.0 mS/cm)
Accuracy ±1 % of reading or ±1 µS/cm, whichever is greater
Calibration • One point using HI9828-25 quick calibration solution
• One point using 84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm solutions or custom point
Resistivity
Range 0 to 999999 Ω·cm; 0 to 1000.0 kΩ·cm (based on reading); 0 to 1.0000 MΩ·cm
Resolution 1 Ω·cm; 0.1 kΩ·cm; 0.0001 MΩ·cm
Calibration Based on conductivity calibration
TDS
Range 0 to 400,000 ppm (mg/L) (Maximum value depends on TDS factor)
Resolution • Manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L)
• Automatic: 1 ppm (0-9999 ppm); 0.01 ppt (10.00-99.99 ppt); 0.1 ppt (100.0-400.0 ppt)
• Automatic (ppt): 0.001 ppt (0.000-9.999); 0.01 ppt (10.00-99.99); 0.1 ppt (100.0-400.0)
Accuracy ±1 % of reading or ±1 ppm (mg/L), whichever is greater
Calibration Based on conductivity or salinity calibration
Salinity
Range 0.00 to 70.00 PSU
Resolution 0.01 PSU
Accuracy ±2% of reading or ±0.01 PSU, whichever is greater
Calibration One point, using a custom solution
Turbidity
Range 0.0 to 99.9 FNU; 100 to 1000 FNU
Resolution 0.1 FNU (0.0-99.9); 1 FNU (100-1000)
Accuracy ±0.3 FNU or ±2 % of reading, whichever is greater
Calibration Automatic; Up to 3 points (0, 20, 200 FNU and custom)
Atmospheric Pressure
Range 450.0-850.0 mmHg | 600.0-1133.2 mbar | 0.5921-1.1184 atm
17.72-33.46 inHg | 8.702-16.436 psi | 60.00-113.32 kPa
Resolution 0.1 mmHg; 0.1 mbar; 0.0001 atm; 0.01 inHg; 0.001 psi; 0.01 kPa
Accuracy ±3.0 mmHg (within ±15 °C of calibration temperature)
Calibration Automatic at one custom point
Temperature
Range - 5.00 to 50.00 °C
Resolution 0.01 °C
Accuracy ±0.15 °C
Calibration Automatic at one custom point

The HI98594 comes fully equipped with a rugged carrying case and all accessories for field use.

All HI98594 models include:

  • HI7698594 multisensor probe
  • HI7698296 probe protector
  • HI76984942 probe maintenance kit
  • HI7698194-1 pH/ORP sensor
  • HI7698594-4 EC/Turbidity sensor
  • HI7698594-5 optical DO sensor
  • HI764113-1 DO Smart Cap with O-ring
  • HI7698293 long calibration beaker
  • HI9828-25 quick calibration standard solution (230 mL)
  • HI7040 zero oxygen solution set (120 mL)
  • HI9829-16 0 FNU calibration solution (230 mL)
  • HI9829-17 20 FNU calibration solution (230 mL)
  • HI9829-18 200 FNU calibration solution (230 mL)
  • HI710036 protective rubber boot
  • HI920016 USB cable
  • 4 × 1.5 V AA alkaline batteries
  • Quality certificates (instrument, probe, DO Smart Cap)
  • Quick reference guide
HI98594/10
10 Items
Comments (0)
No customer reviews for the moment.